CHMFQ - 9A 154 FORMULA P-98
- MSDS: CHMFQ
- Manufacturer: ALLIED ENTERPRISES INC
- Product Name: 9A 154 FORMULA P-98
- National Stock Number: 6850-01-278-4420
Product Identification
Product ID:9A 154 FORMULA P-98
MSDS Date:04/01/1997
FSC:6850
NIIN:01-278-4420
MSDS Number: CHMFQ
Responsible Party
NORFOLK, VA 23508-2008
US
Emergency Phone: 804-489-8282
Info Phone: 804-489-8282
Cage: 58396
Contractor
Telephone: 757-489-8282
Cage: 58396
Ingredients
WATER
CAS: 7732-18-5
RTECS: ZC0110000
Fraction By Weight: TO 100%
TRIPROPYLENE GLYCOL METHYL ETHER
CAS: 10213-77-1
RTECS: UB8050000
Fraction By Weight: 2-8%
POTASSIUM HYDROXIDE (CERCLA)
CAS: 1310-58-3
RTECS: TT2100000
Fraction By Weight: 0-5%
OSHA PEL C 2 MG/M3
ACGIH TLV: C 2 MG/M3; 9596
EPA Report Quantity: 1000 LBS
DOT Report Quantity: 1000 LBS
NONYLPHENOL POLYETHOXATE
CAS: 9016-45-9
RTECS: MD0900000
Fraction By Weight: 0-5%
SODIUM METASILICATE
CAS: 6834-92-0
RTECS: VV9275000
Fraction By Weight: 0-5%
TETRASODIUM ETHYLENE DIAMINE TETRAACETATE
CAS: 64-02-8
RTECS: AH5075000
Fraction By Weight: 0-5%
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:SKIN:SEVERE IRRIT.MAY CAUSE MODERATE
REDDEN,SWELL,POSSIBLE SKIN DMG.EYE:SEVERE IRRIT.LIQ/MSITS MAY DMG
EYES CAUSING CORNEAL DMG.INHAL:VAPS/MISTS MAY BE IRRIT TO MUCOUS
MEMBRANES IN NOSE/THROAT/LUNGS.I NGEST:IRRIT AND CORROSIVE TO
MOUTH/THROAT.MAY CAUSE HEAD,NAU,ABD PAIN,VOMIT,DIARR.EXCESSIVE AMTS
MAY CAUSE COLLAPSE.
Explanation of Carcinogenicity:PER MSDS:INGREDS CARCINOGEN:NO.
Effects of Overexposure:SEVERE SKIN IRRIT,MODERATE
REDDENING/SWELLING,SKIN DMG.SEVERE EYE IRRIT,DMG EYES,CORNEAL
DMG.IRRIT MUC MEMBRANES IN NOSE/THROAT/LUNGS.IRRIT/CORROSIVE TO
MOUTH/THROAT,HEADACHE,NAUSEA,ABDOMINAL PAIN,VOM
ITING,DIARRHEA,COLLAPSE.
Medical Cond Aggravated by Exposure:NONE SPECIFIED BY MANUFACTURER.
First Aid
First Aid:SKIN:FLUSH W/WATER.SEEK MED ATTN IF IRRIT PERSISTS.EYE:FLUSH
W/LG QUANT OF WATER,HOLDING EYELIDS OPEN.SEEK MED ATTN IF IRRIT
PERSISTS.INHAL:GET TO FRESH AIR.SEEK MED ATTN IF IRRIT
PERSISTS.INGEST:DONT INDUCE VOMIT.DRINK LG QUANT OF WATER.SEEK MED
ATTN IMMED.
Fire Fighting
Flash Point:NA
Autoignition Temp:Autoignition Temp Text:NP
Lower Limits:NA
Upper Limits:NA
Fire Fighting Procedures:NON-FLAMMABLE.
Accidental Release
Spill Release Procedures:MOP UP OR OTHERWISE ABSORB AND HOLD FOR
DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:AVOID CONTACT
W/EYES/SKIN/CLOTHING.KEEP OUT OF REACH OF CHILDREN.FOR USE BY
TRAINED PERSONNEL ONLY.KEEP CNTNR CLSD DURING STORAGE.
Other Precautions:FOR INSTITUTIONAL AND INDUSTRIAL USE ONLY.
Exposure Controls
Respiratory Protection:USE IN WELL VENTILATED AREA.
Ventilation:PROVIDE LOCAL EXHAUST TO KEEP TLV OF INGREDS BELOW
ACCEPTABLE LIMIT.
Protective Gloves:CHEMICAL RESIST RUBBER OR NEOPRENE
Eye Protection:SAFETY GLASSES
Other Protective Equipment:EYEWASH STATION,CHEMICAL RESISTANT APRON.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
Chemical Properties
HCC:B1
Boiling Pt:B.P. Text:210F,99C
Melt/Freeze Pt:M.P/F.P Text:NP
Decomp Temp:Decomp Text:NP
Vapor Pres:20
Vapor Density:>1
Spec Gravity:1.042
pH:11.+-5
Viscosity:NP
Evaporation Rate & Reference:<1, WATER=1
Solubility in Water:COMPLETE
Appearance and Odor:THIN CLEAR LIQUID WITH CHARACTERISTIC ODOR
Percent Volatiles by Volume:85+
Corrosion Rate:NP
Stability
Stability Indicator/Materials to Avoid:YES
STRONG ACIDS
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:ALKALINE VAPORS IN A FIRE.
Disposal
Waste Disposal Methods:CONTAINS NO TOXIC CHEM SUBJ TO REPORT REQMTS OF
SEC 313 EPCRA/40CFR372.ANY METHOD IN ACCORDANCE WITH APPLICABLE
LAWS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.